logo
Haus > produits >
Kabelfehlerlocker
>
Precision and Reliability Cable Fault Locator for Accurate Testing and Diagnostics

Precision and Reliability Cable Fault Locator for Accurate Testing and Diagnostics

Produktdetails:
Herkunftsort: Xi'an
Markenname: XZH TEST
Zertifizierung: CE
Modellnummer: XHGG510S
Ausführliche Information
Herkunftsort:
Xi'an
Markenname:
XZH TEST
Zertifizierung:
CE
Modellnummer:
XHGG510S
Hervorheben:

High Light

Hervorheben:

Precision Cable Fault Locator

,

Reliability Cable Fault Detector

,

Testing Cable Tester

Trading Information
Min Bestellmenge:
1 Satz
Verpackung Informationen:
Holzverpackung
Lieferzeit:
5-8 ARBEITSTAGE
Zahlungsbedingungen:
T/T
Versorgungsmaterial-Fähigkeit:
3000 Einheiten/Jahr
Produkt-Beschreibung
XHGG510S
Urbanization acceleration brings larger cities and surging annual electricity demand, gradually replacing traditional overhead power lines with cable systems. Popularization and training of power cable fault detectors have long been problematic. To solve this, our independently developed power cable fault simulator can simulate all fault types of power cables. The device distills decades of expertise in China's power cable fault detection sector.

Main Technical Parameters:

1. Low Resistance Fault Simulator: 0Ω~Several Hundreds of Ω

2. Open Circuit Fault Simulator: Several Ω~∞

3. Leakage High Resistance Fault Simulator: Several Ω~Hundreds of MΩ

4. Flashover High Resistance Fault Simulator: Flashover Voltage Range Several kV~Hundreds of kV

5. Continuous Operating Time: 8 hours

6. Operating Conditions:

a. Ambient Temperature: -30℃~ +70℃

b. Relative Humidity (RH) ≤ 85% (25℃)

c. Altitude: h ≤ 1000m

Precision and Reliability Cable Fault Locator for Accurate Testing and Diagnostics 0

Simulation Box Structure This power cable fault simulator box consists of four different types of fault simulators (low resistance, open circuit, high leakage resistance, and high flashover resistance). They are arranged parallel to each other within the simulation box, and are insulated from each other and from ground by support insulators mounted on elbow-shaped plug-in components inside the box.

Precision and Reliability Cable Fault Locator for Accurate Testing and Diagnostics 1

Precautions for Use

1. This power cable fault simulator box should be reliably grounded and meet the grounding resistance requirements specified in relevant regulations.

2. During simulated fault testing, the rear door of the fault simulator box should be closed to prevent personnel from accidentally entering and being electrocuted by high voltage.