logo
Haus > produits >
Kabelfehlerlocker
>
Cable Fault Locator with Built-in 8μF Capacitor and 0~900J Discharge Energy for High Voltage Surge Testing

Cable Fault Locator with Built-in 8μF Capacitor and 0~900J Discharge Energy for High Voltage Surge Testing

Produktdetails:
Herkunftsort: Xi'an Shaanxi China
Markenname: XZH TEST
Zertifizierung: ISO CE
Modellnummer: Die in Absatz 1 genannten Anforderungen gelten nicht für die in Absatz 1 genannten Fahrzeuge.
Ausführliche Information
Herkunftsort:
Xi'an Shaanxi China
Markenname:
XZH TEST
Zertifizierung:
ISO CE
Modellnummer:
Die in Absatz 1 genannten Anforderungen gelten nicht für die in Absatz 1 genannten Fahrzeuge.
Hervorheben:

High Light

Hervorheben:

Built-in capacitor 8μF Cable Fault Locator

,

Discharge energy 0~900J Cable Fault Detector

,

High voltage surge generator Cable Tester

Trading Information
Min Bestellmenge:
1 Satz
Verpackung Informationen:
Holzverpackung
Lieferzeit:
5-8 ARBEITSTAGE
Zahlungsbedingungen:
T/T
Versorgungsmaterial-Fähigkeit:
3000 Einheiten/Jahr
Produkt-Beschreibung
XHHV515-8L
Product Overview
It is mainly used for impulse discharge during fault testing of cables with voltage levels of 15kV and below; it can also be used for DC withstand voltage testing of other electrical equipment.
Key Specifications
Impulse voltage: 0~15kV
Short circuit current: 0~320mA
High voltage accuracy: Class 1.5
Built-in capacitor: 8μF
Discharge energy: 0~900J
Key Features
  • It features automatic overcurrent, overvoltage, and overheat protection;
  • DC withstand voltage and impulse discharge capabilities;
  • uniform and controllable high-voltage pulse output; and superior short-circuit protection, allowing the high-voltage output to operate directly short-circuited to ground.

    Cable Fault Locator with Built-in 8μF Capacitor and 0~900J Discharge Energy for High Voltage Surge Testing 0

Instrument Components:

1. Main Unit: Applies high-voltage, high-energy pulse signals to the cable under test;

2. High-Voltage Output Line: Connects the high-voltage output terminal of the main unit to the core of the cable under test;

3. Ground Wire: Safety ground and grounding wire for the discharge rod;

4. Power Cord: The instrument's operating power cord;
5. Fuse: A spare fuse for the AC220V power supply system;

6. Discharge Rod: Performs DC current-limited discharge or DC short-circuit discharge on the cable under test.