Cable Fault Locator with Built-in Capacitor and Three-Level Adjustment for Precise Detection

Cable Fault Locator with Built-in Capacitor and Three-Level Adjustment for Precise Detection

Produktdetails:
Herkunftsort: Xi'an Shaanxi China
Markenname: XZH TEST
Zertifizierung: ISO CE
Modellnummer: XHHV535-2TS
Ausführliche Information
Herkunftsort:
Xi'an Shaanxi China
Markenname:
XZH TEST
Zertifizierung:
ISO CE
Modellnummer:
XHHV535-2TS
Hervorheben:

High Light

Hervorheben:

Built-in capacitor Cable Fault Locator

,

Three-level adjustment Cable Fault Detector

,

Precise detection Cable Tester

Trading Information
Min Bestellmenge:
1 Satz
Verpackung Informationen:
Holzverpackung
Lieferzeit:
5-8 ARBEITSTAGE
Zahlungsbedingungen:
T/T
Versorgungsmaterial-Fähigkeit:
3000 Einheiten/Jahr
Produkt-Beschreibung

XHHV535-2TS

t is mainly used for impulse discharge and withstand voltage tests during low- and high-voltage cable fault testing.The high-voltage pulse generator fully complies with DL/T846-2016 "General Technical Conditions for High Voltage Test Equipment" and DL/T474-2017 "Implementation Guidelines for Field Insulation Tests".


Product Features:

Uniform and controllable high-voltage pulse output;

Dual 2.5-level pointer meter display for current and voltage, providing clear and intuitive readings of the impact discharge process;

Real-time and accurate high-voltage side measurement;

Zero-point start protection function for safety and reliability;

Three voltage ranges and capacitor capacity switching function;

Unique high-voltage measurement design automatically discharges the internal capacitor when stopped;

 Discharge time can be selected in timed and manual modes;

 DC withstand voltage function;

Internally installed high-precision test cable fault sampling waveform module;

User-friendly handcart design for easy movement;


Working Principle

Before using the high-voltage pulse generator, select the appropriate function switch and voltage range switch, then press the start button to increase the high voltage. The test cable will then be tested following the procedure shown in the diagram. After use, the internal system will automatically discharge the remaining high voltage from the energy storage device, and this will be indicated on the voltmeter. The workflow diagram is as follows:

Cable Fault Locator with Built-in Capacitor and Three-Level Adjustment for Precise Detection 0


Side panel description

1. Power Socket (220V 50Hz): Power supply for the instrument, AC220V connection port;

2. Fuse Holder: Fuse holder for the AC220V power supply system;

3. Signal Connector: Uses a dual-Q cable to connect the instrument to the cable fault tester for flashover waveform acquisition. Only effective during high-voltage flashover.

Cable Fault Locator with Built-in Capacitor and Three-Level Adjustment for Precise Detection 1